CORONA PLAZA CENTRO COMERIAL 1
CORONA PLAZA CENTRO COMERIAL 2

CORONA PLAZA SHOPPING CENTER

Peru, TUMBES · 2016
Categoy: Commertial building, SHOPPING CENTER
Construction surface (m2): 6.000
Specialization: AIR CONDITIONING, VENTILATION, PUMP
Installation of 1 air-cooled chiller with a capacity of 100 Tn and two water-cooled chillers with a capacity of 500 Tn each. Two 500 Tn cooling towers. 15 cold water pumps and 3 condensate pumps. Pressurizing of 4 stairs. Monoxide extraction system for two basement levels. BMS system and centralized control.
LOCAL COMERCIAL EN BEGONIAS

COMMERCIAL VENUE IN BEGONIAS

Peru, LIMA · 2017
Categoy: Commertial building, COMMERCIAL VENUES
Construction surface (m2): 2.000
Specialization: AIR CONDITIONING
Air conditioning of store and warehouse areas using TRANE VRF units with a capacity of 140 Tn.
LOCAL COMERCIAL EN BEGONIAS

COMMERCIAL VENUE IN BEGONIAS

Peru, LIMA · 2017
Categoy: Commertial building, COMMERCIAL VENUES
Construction surface (m2): 500
Specialization: AIR CONDITIONING
Air conditioning of store and warehouse areas using TRANE VRF units with a capacity of 45 Tn.
LOCAL COMERCIAL EN C.C. MEGAPLAZA LOS OLIVOS 1

COMMERCIAL VENUE IN C.C. MEGAPLAZA LOS OLIVOS

Peru, LIMA · 2016
Categoy: Commertial building, COMMERCIAL VENUES
Construction surface (m2): 1.800
Specialization: AIR CONDITIONING
Air conditioning of store and warehouse areas using MIDEA VRF units with a capacity of 135 Tn.
LOCAL COMERCIAL EN C.C. SALAVERRY 1

COMMERCIAL VENUE IN C.C. SALAVERRY

Peru, LIMA · 2014
Categoy: Commertial building, COMMERCIAL VENUES
Construction surface (m2): 2.000
Specialization: AIR CONDITIONING
Air conditioning of store and warehouse areas using two Aermec coolers with a capacity of 60 Tn.
LOCAL COMERCIAL EN C.C. SALAVERRY

COMMERCIAL VENUE IN C.C. SALAVERRY

Peru, LIMA · 2014
Categoy: Commertial building, COMMERCIAL VENUES
Construction surface (m2): 250
Specialization: AIR CONDITIONING
Air conditioning of store and warehouse areas using HITECSA coolers with a total capacity of 27 Tn.
PLANTA MOLITALIA ALIMENTOS MASCOTAS 1

MOLITALIA PETFOOD PLANT

Peru, LIMA · 2016
Categoy: Commertial building, INDUSTRIAL PLANT
Construction surface (m2): 10.000
Specialization: AIR CONDITIONING, VENTILATION, FP, PUMP
Fire detection and extinguishing system using a 2,000 GLP pump, sprinkler network, cabinets and fire hydrants. Ventilation system for warehouses and process plant. Air conditioning in offices.
TIENDA SODIMAC 1

SODIMAC STORE IN CAÑETE

Peru, CAÑETE · 2013
Categoy: Commertial building, COMMERCIAL VENUES
Construction surface (m2): 3.500
Specialization: FP, PUMP
Detection and extinguishing system using a 750 GLP motor pump, sprinkler network, cabinets and fire hydrants.